Search results for "Fiber reinforced polymer"
showing 10 items of 18 documents
A Mechanical Approach for Evaluating the Distribution of Confinement Pressure in FRP-Wrapped Rectangular Columns
2019
In recent decades, fiber reinforced polymer (FRP) wrapping has become a common technique to retrofit reinforced concrete (RC) columns. Numerous research works have sought to verify analytically and experimentally its effectiveness in terms of enhancement of axial load bearing capacity and ductility. These studies highlighted that in the case of sharp-cornered sections, the maximum allowable confinement pressure is limited by premature failure at corners and, consequently, stress in the FRP, as well as the distribution of the confinement pressure, is not uniform. The prediction of this phenomenon is not straightforward, and existing theoretical studies propose complex numerical simulations, …
Analysis of the mechanical performance of hybrid (SPR/bonded) single-lap joints between CFRP panels and aluminum blanks
2013
Abstract The increasing use of innovative materials in manufacturing of modern mechanical components has led to the development of reliable joints between innovative (composite materials etc.) and traditional materials (steel, aluminum etc.). In the last few years, hybrid joints, combining the advantages of the adhesive joints and traditional mechanical joints as bolted or riveted joints, have been shown an increasing industrial interest especially in automotive and aerospace sectors. In the present paper a systematic experimental study of hybrid lap joints was carried out with the aim to detect the optimal joint configuration. Tensile tests on hybrid joints made by combining adhesive bondi…
Experimental investigation on the compressive behavior of short-term preloaded carbon fiber reinforced polymer-confined concrete columns
2017
Strengthening of concrete columns with fiber reinforced polymer sheets provides a good improvement to the existing structural members in terms of load and strain capacity due to the properties of the composite jacket. A proper knowledge of the load–strain response of the composite members is necessary to design retrofitting intervention of existing structures; however, so far the available design methods do not allow to take into account the effect of the possible presence of service loads on the compressive behavior of the reinforced columns. An experimental investigation on the compressive behavior of preloaded circular concrete columns reinforced with carbon fiber reinforced polymer was …
Structural performances of pultruded GFRP emergency structures – Part 2: Full-scale experimental testing
2019
Abstract This paper presents an experimental testing of a pultruded glass fiber reinforced polymer (FRP) structure used for emergency applications continuing the discussion presented in a previous paper (part 1) where the study of the characteristics of material and elements are presented. First, the design of the composite structure and components and the evaluation of the structural behavior by means of numerical and analytical approach according to current regulatory codes are described. In this frame, the global and local response was observed according to load paths deriving from the design loads at limit states. Then, the experimental test on a full-scale 2D model is presented at diff…
Behavior in compression of concrete cylinders externally wrapped with basalt fibers
2015
Abstract This paper gives additional information on the use of new class of composites constituted by Basalt Fiber Reinforced Polymer (BFRP) bonded with epoxy resin to concrete specimens as an alternative confinement material for compressed concrete members with respect to carbon or glass fibers. From the experimental point of view, concrete cylinders are wrapped with continuous fibers, in the form of sheets, applying both full and partial discrete wrapping with BFRP straps, and then tested in compression. For comparison, few other concrete cylinders are wrapped with Carbon Fiber Reinforced Polymer (CFRP) sheets and tested in compression. The number and type of plies (full or partial wrappi…
Stress-Strain Law for Confined Concrete with Hardening or Softening Behavior
2013
This paper provides a new general stress-strain law for concrete confined by steel, fiber reinforced polymer (FRP), or fiber reinforced cementitious matrix (FRCM), obtained by a suitable modification of the well-known Sargin’s curve for steel confined concrete. The proposed law is able to reproduce stress-strain curve of any shape, having both hardening or softening behavior, by using a single closed-form simple algebraic expression with constant coefficients. The coefficients are defined on the basis of the stress and the tangent modulus of the confined concrete in three characteristic points of the curve, thus being related to physical meaningful parameters. It will be shown that if the v…
Ductility of Reinforced Concrete Members Externally Wrapped with Fiber-Reinforced Polymer Sheets
2007
The effectiveness of external wrapping with fiber-reinforced polymer for enhancing the curvature ductility of lightly reinforced concrete members is investigated. Referring to members with circular transverse cross sections, the performances in terms of both strength and ductility capacities are analyzed, and the predictive reliability of two different recent constitutive models, available in the literature and able to take into account the softening behavior of confined concrete, is checked. A parameter characterizing the effectiveness of the confining wrapping is proposed, and characteristic values are suggested. Moreover, referring to ductility increases due to confinement effects, a com…
Effect of FRP Wraps on the Compressive Behaviour of Slender Masonry Columns
2017
In the last decade, Fibre Reinforced Polymer (FRP) wrapping technique has become a common method to retrofit masonry piers or columns with poor structural performances. The passive confinement effect induced by the external wrap allows increasing the compressive strength and ductility of the member. Several studies highlighted as the efficacy of this technique is affected by several key parameters, including the shape of the transverse cross section, stress intensification at the strength corner of sharp sections, amount and mechanical properties of adopted composite. Despite this technique has been widely studied from both theoretical and experimental point of view, most of studies focused…
Design av en offshore gangbru i fiberarmert polymer
2018
Masteroppgave bygg BYG508 - Universitetet i Agder 2018 Innovation and development are essential for a market in demand of faster, lighter and stronger solutions. As a material with high strength to weight ratio, and good possibilities of being premade, fiber reinforced polymers can meet those requirements. However, it has yet to challenge concrete, steel and aluminum as a structural material. This is the underlying challenge for the problem statement of this assignment, to construct an offshore gangway using fiber reinforced polymers. The design concept is based on existing steel and aluminum constructions within the size range of 25- 30m fully extended. To solve the problem and answer the …
Structural performances of pultruded GFRP emergency structures – Part 1: Experimental characterization of materials and substructure
2019
Abstract This paper presents an experimental study in the field of structures made of pultruded fiber reinforced polymers (FRP) elements to be used for emergency purposes. A preliminary design of a 3D pultruded glass fiber reinforced polymer structure is presented with the mechanical characterization of the constituting elements. The axial and flexural properties of laminate and I-shaped GRFP profiles are discussed considering the short term creep. In a companion paper, the benefits, the limits and the reliability of the structure analyzed for emergency applications are discussed. In details, the numerical structural analysis of the full-scale 3D model is described followed by the experimen…